Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Pharmaceutical Analysis ; (6): 309-316, 2017.
Article in Chinese | WPRIM | ID: wpr-658083

ABSTRACT

A sensitive and selective method has been proposed for the simultaneous determination of amlodipine (AML), valsartan (VAL) and hydrochlorothiazide (HCTZ) in human plasma by liquid chromatography–tandem mass spectrometry (LC–MS/MS). The analytes and their deuterated analogs were quantitatively extracted from 100 μL human plasma by solid phase extraction on Oasis HLB cartridges. The chromatographic separation of the analytes was achieved on a Chromolith RP18e (100 mm × 4.6 mm) analytical column within 2.5 min. The resolution factor between AML and VAL, AML and HCTZ, and VAL and HCTZ was 2.9, 1.5 and 1.4, respectively, under isocratic conditions. The method was validated over a dynamic concentration range of 0.02–20.0 ng/mL for AML, 5.00–10,000 ng/mL for VAL and 0.20–200 ng/mL for HCTZ. Ion-suppression/enhancement effects were investigated by post-column infusion technique. The mean IS-normalized matrix factors for AML, VAL and HCTZ were 0.992, 0.994 and 0.998, respectively. The intra-batch and inter-batch precision (% CV) across quality control levels was ≤ 5.56% and the recovery was in the range of 93.4%–99.6% for all the analytes. The method was successfully applied to a bioequivalence study of 5 mg AML + 160 mg VAL + 12.5 mg HCTZ tablet formulation (test and reference) in 18 healthy Indian males under fasting. The mean log-transformed ratios of Cmax, AUC0–120h and AUC0-inf and their 90% CIs were within 90.2%–102.1%. The assay reproducibility was demonstrated by reanalysis of 90 incurred samples.

2.
Journal of Pharmaceutical Analysis ; (6): 309-316, 2017.
Article in Chinese | WPRIM | ID: wpr-660806

ABSTRACT

A sensitive and selective method has been proposed for the simultaneous determination of amlodipine (AML), valsartan (VAL) and hydrochlorothiazide (HCTZ) in human plasma by liquid chromatography–tandem mass spectrometry (LC–MS/MS). The analytes and their deuterated analogs were quantitatively extracted from 100 μL human plasma by solid phase extraction on Oasis HLB cartridges. The chromatographic separation of the analytes was achieved on a Chromolith RP18e (100 mm × 4.6 mm) analytical column within 2.5 min. The resolution factor between AML and VAL, AML and HCTZ, and VAL and HCTZ was 2.9, 1.5 and 1.4, respectively, under isocratic conditions. The method was validated over a dynamic concentration range of 0.02–20.0 ng/mL for AML, 5.00–10,000 ng/mL for VAL and 0.20–200 ng/mL for HCTZ. Ion-suppression/enhancement effects were investigated by post-column infusion technique. The mean IS-normalized matrix factors for AML, VAL and HCTZ were 0.992, 0.994 and 0.998, respectively. The intra-batch and inter-batch precision (% CV) across quality control levels was ≤ 5.56% and the recovery was in the range of 93.4%–99.6% for all the analytes. The method was successfully applied to a bioequivalence study of 5 mg AML + 160 mg VAL + 12.5 mg HCTZ tablet formulation (test and reference) in 18 healthy Indian males under fasting. The mean log-transformed ratios of Cmax, AUC0–120h and AUC0-inf and their 90% CIs were within 90.2%–102.1%. The assay reproducibility was demonstrated by reanalysis of 90 incurred samples.

3.
Journal of Pharmaceutical Analysis ; (6): 163-169, 2017.
Article in Chinese | WPRIM | ID: wpr-686694

ABSTRACT

A sensitive and rapid liquid chromatography-tandem mass spectrometry (LC– MS/MS) method has been developed for the simultaneous determination of lisinopril (LIS) andhydrochlorothiazide (HCTZ) in human plasma using their labeled internal standards (ISs). Sample pre-treatmentinvolved solid phase extraction on Waters Oasis HLB cartridges using 100 μL of plasma, followed by liquidchromatography on Hypersil Gold C18 (50 mm×3.0 mm, 5 μm) column. The analytes were eluted within 2.0 min usingacetonitrile-5.0 mM ammonium formate, pH 4.5 (85:15, v/v) as the mobile phase. The analytes and ISs wereanalyzed in the negative ionization mode and quantified using multiple reaction monitoring. The methodshowed excellent linearity over the concentration range of 0.50–250.0 ng/mL for both the analytes. Theintra-batch and inter-batch precision (% CV) was ≤5.26% and their extraction recoveries were in the range of 96.6% –103.1%. Matrix effect evaluated in terms of IS-normalized matrix factors ranged from 0.97 to 1.03 for boththe analytes. The validated method was successfully applied to determine the plasma concentration of the drugsusing 10 mg lisinopril and 12.5 mg hydrochlorothiazide fixed dose formulation in 18 healthy Indian volunteers.

SELECTION OF CITATIONS
SEARCH DETAIL